Data
  • In progress
  • Data

    Data validation

    Data validation validates if pipe or zone parameters are synchronised.

    General

    Inner diameter {diameter} of {diameter name} in Hysopt does not match inner diameter {diameter} of mapped diameter {diameter name} in BIM

    Pipe

    Pipe diameter in BIM (Size …) and Hysopt (DN …) are the same

    Pipe length in BIM (… m) and Hysopt (… m) are the same

    Pipe zeta in BIM (…) and Hysopt (…) are the same

    Missing diameter mapping for the BIM pipe, map the pipe diameter to enable diameter synchronisation

    Missing diameter mapping for the Hysopt pipe, map the pipe diameter to enable diameter synchronisation

    Missing diameter mapping for the BIM and Hysopt pipe, map the pipe diameter to enable diameter synchronisation

    This BIM Branch contains one or more pipes with a diameter that does not correspond to the predefined ‘segments and sizes’

    Fittings are missing required parameters, not possible to calculate and verify zeta values

    Pipe contains undefined fittings, not possible to calculate and verify zeta values

    Pipe contains fittings for which the type is not present, not possible to calculate and verify zeta values

    Pipe contains unknown fittings ({fitting type names}), not possible to calculate and verify zeta values

    Hysopt pipe contains nodes for which we could not calculate all necessary info, not possible to calculate and verify zeta values

    Could not calculate the zeta values for the fittings

    Synchronise to Revit:

    Pipe diameter in BIM (Size …) and Hysopt (DN …) are not the same

    Pipe length in Hysopt ({meters} m) exceeds 0.5m, while pipe length in BIM is zero

    This Hysopt branch consists of pipe segments with different diameters

    Synchronise to Hysopt:

    Pipe diameter in BIM (size … ) and Hysopt (DN …) are not the same

    Pipe length in BIM (… m) and Hysopt (… m) are not the same

    Pipe length in BIM ({meters} m) exceeds 0.5m, while pipe length in Hysopt is zero

    Pipe zeta in BIM (…) and Hysopt (…) are not the same

    This BIM branch consists of pipe segments with different diameters. Pipe diameter in BIM (multiple diameters) and Hysopt {diameter name} are not the same

    Zone

    Zone volume in BIM (… m³) and Hysopt (… m³) are the same

    Synchronise to Revit:

    Synchronise to Hysopt:

    Zone name in BIM (Space #) and Hysopt (<empty>) are not the same

    Zone volume in BIM ({volume} m3) and Hysopt ({volume} m3) are not the same

     

    Related content