Your newly created model is opened after following theCreating your first project page. The opened model contains a lot of different buttons and drop-down menus. We will explain all these on this page.

image-20241028-085840.pngImage Added

1. The optimiser tab buttons

...

These buttons will bring you to the four different tabs the optimiser contains.

Button logo

Name

Explanation

More information

Image Added

Designer

This tab lets you work on the models

https://hysopt.atlassian.net/wiki/spaces/HRM/pages/3089530882/Drawing+your+first+model

Image Added

Inspiration library

This tab contains different pre-made and working models that you can insert into your model. This way you don’t have to start drawing your models from scratch.

https://hysopt.atlassian.net/wiki/spaces/HRM/pages/3089368928/Inspiration+Library+-+Wizard

Image Added

Sensitivity analysis

Sensitivity analysis is used to thoroughly examine the correct dimensions of the system by simultaneously simulating different models, each having a minor difference from the reference.

https://hysopt.atlassian.net/wiki/spaces/HRM/pages/3089206234/Sensitivity+Analysis

Image Added

Pareto

Pareto analysis is used to analyse different concepts or models with each other. The analysation is done by comparing the KPIs (Key Performance Indicators) of every model.

Pareto analysis: usage

2. Log out button

This button lets you log out of the Hysopt optimiser application.

3. Layers and libraries

These buttons contain all the different libraries you need to make a working model.

Button logo

Name

Explanation

More information

Image Added

Heating library

This button contains everything that you need to use for a heating circuit

https://hysopt.atlassian.net/wiki/spaces/HRM/pages/3089203864

Image Added

Cooling library

This button contains everything that you need to use for a cooling circuit

https://hysopt.atlassian.net/wiki/spaces/HRM/pages/3089206007/Cooling+Library

Image Added

Zones library

This button contains everything that you need to use for drawing the zones of radiators

Zone library

Image Added

Control library

This button contains everything that you need to use for drawing the controls of your model

https://hysopt.atlassian.net/wiki/spaces/HRM/pages/3089370593/Controls

Image Added

Text library

This button contains everything that you need to use for drawing text labels

No extra information is available.

4. Tools

Button logo

Library

Name

Explanation

Image AddedImage Added

Select

This is used to select one or multiple items on the drawing canvas.

Image AddedImage Added

Two pipe

This is used to draw two pipes (supply and return). This is the kind of pipe that you as a user will mostly use.

Image AddedImage Added

Header

This is used to draw a header. This pipe is used in places where one pipe arrives and multiple pipes leave.

Image AddedImage Added

Reverse return

The reverse return pipe is used so that the length of the circuit through the supply and return piping to each end unit is essentially the same. Therefore, balancing is almost unnecessary.

Image AddedImage Added

Changeover

This pipe can be used in a system where both heating and cooling connections are made through the same pipe.

Image AddedImage Added

Three pipe

This piping offers a significant reduction in installation costs and pipework compared with traditional four-pipe systems. Three-pipe systems can provide full heating and/or cooling to any room at any time.

Image AddedImage Added

Canvas Link

This is used to draw links between canvasses. This is needed as Hysopt is a 2D -modelling software.

Image AddedImage Added

Draw zone

This is used to draw zones which you can assign to the Base circuit ‘Radiator/Convector’. A zone is the equivalent of the room where the radiator/convector is located.

Image AddedImage Added

Assign to zone

Can be used to assign a radiator to a zone.

Image AddedImage Added

Unassign from zone

This button can be used to unassign a radiator from a zone.

Image AddedImage Added

Draw

Lets you draw control lines that are used to connect control base circuits or with base circuits.

Image AddedImage Added

Assign to the electric meter box*

This button can be used to assign an electric consumer to an electric meter box.

Image AddedImage Added

Unassign from the electric meter box*

This button can be used to unassign an electric consumer from an electric meter box.

Image AddedImage Added

Assign to fuel meter box*

This button can be used to assign a fuel consumer to a fuel meter box.

Image AddedImage Added

Unassign from the fuel meter box*

This button can be used to unassign a fuel consumer from a fuel meter box.

Image AddedImage Added

Insert label

Can be used to create text labels where you can write your comments etc. in.

Image AddedImage Added

Insert dynamic label

Can be used to create dynamic labels by clicking base circuits while this button is active.

* More info about the meter boxes is found on the page https://hysopt.atlassian.net/wiki/spaces/HRM/pages/3089368564/Meter+boxes

5. Hysopt Library

5a. Base Circuit Library

This contains all the different base circuits you might need to draw a model. Base circuits are the building blocks of your model in which you can fill in specific properties of that base circuit. Base circuits can be divided into three major classes, namely production units, end units and in-between units. The illustration below shows a heating circuit on which these classes are indicated.

...

The difference between those classes is explained in the table below.

Name

Explanation

Production units

These BCs provide power to the circuit and has 1 node were you connect the pipes to.

In-between units

These BC’s makes it possible to add different hydraulic structures which require different calculations to your model. These blocks have 2 nodes where you connect those pipes to.

End units

These BCs consume the power of the circuit and has 1 node to connect pipes to.

In the table below you find all the BCs of the illustration with the classes and the library where to find them to explain the structure of the basic library. All of the BCs come from the heating library but don’t worry, the cooling library has the same structure.

BC

Location

Image AddedImage Added

Image Added
Image AddedImage Added
Image AddedImage Added

Image AddedImage Added

Image Added
Image AddedImage Added

Image Added
Image AddedImage Added
Image AddedImage Added
Image AddedImage Added

5b. Snippet library

As part of the Hysopt BC library, Hysopt also provides commonly-used configurations for a particular BC under the form of snippets. Snippets can be accessed by clicking the expand icon image-20240827-115834.pngImage Added in the bottom-right corner of a base circuit in the library. The expand icon will open the snippet pop-up window with all available snippets for that particular base circuit. When selecting a snippet from the pop-up window, the snippet is pasted as a group onto your canvas. More information about snippets can be here: snippets

...

6. File buttons

Button logo

Name

Explanation

Image Added

Open model explorer

The model explorer is used to open/create new models/folders, import models with tokens and move folders and models.

Image Added

Save model

This is used to save your model.

Image Added

Copy model

This opens a pop-up screen where you can give your current model another name and another location. This is the same as a ‘save as' function.

Image Added

Insert model

This can be used to insert another model in your currently opened model.

Image Added

Export as…

Exports the model as different file types. The possible file types are: JSON, PDF & DXF. More information about the export possibilities is found on the https://hysopt.atlassian.net/wiki/spaces/HRM/pages/3089367755/Exports page.

7. Model name

This is the name you gave your model during model creation.

8. Compute actions

Button logo

Name

Explanation

More information

Image Added

System check

'System check' will check the model for hydraulic mistakes and inconsistencies but this will not check the capacities.

https://hysopt.atlassian.net/wiki/spaces/HRM/pages/3089203395/Model+validation

Image Added

Compute design flows

This action calculates the design flows based on the filled in parameters.

https://hysopt.atlassian.net/wiki/spaces/HRM/pages/3089367213/Compute+design+flows

Image Added

Select pipes

This action selects the pipes based on the filled in parameters and filtering criteria.

https://hysopt.atlassian.net/wiki/spaces/HRM/pages/3089367328

Image Added

Optimise components

This action optimises the valves and pumps.

https://hysopt.atlassian.net/wiki/spaces/HRM/pages/3089367389/Optimize+pumps+and+valves

Image Added

Simulate

This action requires the use of components in the control library to simulate the dynamic behaviour of the system.

https://hysopt.atlassian.net/wiki/spaces/HRM/pages/3089367697/Dynamic+simulation

9. Canvas management, operations and model settings

Button logo

Name

Explanation

Image Added

Canvas selection and management

Canvas management & Floor plan implementation

Image Added

Layers

This button can be used to toggle different visualisation layers. For example, the Hysopt user can choose to hide zones, text, controls, grids, or floor plans on the active Canvas

Image Added

Create report

https://hysopt.atlassian.net/wiki/spaces/HRM/pages/3089367755/Exports

Image Added

Search

Can be used to search for components in your model.

Image Added

Operations

Gives a screen of different operations you can use and the shortcuts for these operations.

Image Added

Model settings

This lets you change the units, diversity standard and many more settings of your current model.

10. User settings & Support buttons

Button logo

Name

Explanation

Image Added

User settings

Lets you change user-specific settings.

Image Added

Help

Contains a link to the https://hysopt.atlassian.net/wiki/spaces/HRM or lets you contact one of our Hysopt experts.

11. Perspectives

To prevent the software from becoming too confusing, some buttons or parameters of base circuits are hidden behind layers. Perspectives are used to reveal these hidden layers.

Perspective logo

Name

Explanation

image-20241028-090700.pngImage Added

Advanced

Enables you to show or hide parameters classified as "Advanced”, allowing you to focus on essential, easy-to-understand parameters.

Image Added

Simulation

Enables you to show or hide parameters that are only relevant for simulation purposes. This layer is used to parameterise the dynamic behaviour of the installation.

image-20241028-090942.pngImage Added

Partial load analysis

Allows you to analyse the model in partial load. This layer is mostly used to analyse balancing and valve authorities in partial load situations.

Image Added

Sensitivity Analysis

Allows you to highlight certain base circuit parameters that you want to adapt in a sensitivity analysis.

12. Drawing canvas

This is the space where you can draw your model. You can draw models by dragging and dropping base circuits on the canvas and connecting these by pipes and control lines.