The tagging mechanism has changed. Assigning and deleting tags can now be done in the new tab “Tags”. If you desire to look for a tag or ID a new search area is available on the top left corner of your canvas screen. Everything is documented on our Wiki page with the following link: Assigning tags and searching for tags and/or IDs
A load duration curve for electricity is added as a simulation graph for the CHPs.
The user can now choose if the exported floor plan is zoomed in on the schematic on the floor plan or the floor plan itself.
Some minor bug fixes
Changes as of
The look and feel of the Base Circuit library has been restyled and improved
The speed to create the Pareto dashboard has been doubled
The Volume Weighted and Power Weighted Return Temperature (VWRT and PWRT) are added to all sensor BCs.
A warning is added when implementing your data in the data file BC to specify when to set the "relativity to simulation start time" parameter. On the top right corner, there is also a link to our wiki page where everything is more thoroughly explained. (Generators)
Some minor bug fixes
Changes as of
The volume calculation method for expansion vessels is separated. The pipe volume and storage vessel volume is visualised separately from the "system volume" which is calculated using the DFTK17 method of 10 liters/kW installed power.
Some minor bug fixes
Changes as of
2 new BCs have been added, a “Design Condition Override” for both heating and cooling. These BCs have the possibility to change and lock the thermal power and/or the temperature regime. More information can be found in: System peripherals
Some minor bug fixes
Changes as of
The Standard Tap Profile Generator BC now also has a re-randomize function. This means that in default the tap profile generator doesn’t change anymore with every new executed simulation. The user can set the re-randomize on when the tap profile in the current simulation isn’t desirable. This function was already active for the Eco-Design Tap Profile Generator.
Some minor bug fixes
Changes as of
We added a new component : insulation on heat exchangers
We added the possibility to do sensitivity analysis on zone parameters, which can be used for (semi) automated load matching
Some minor bug fixes
Changes as of
We added a new simulation method for DPCV's (P-control over multiple timesteps) which can be activated if you experience simulation difficulties with the default simulation method seeFrequently Asked Questionsfor more info
Some minor bug fixes
Changes as of
We added the possibility to export Pareto graphs using the export icon
We added 2 graphs to the Pareto dashboard
Normal heat exchangers now have the same UA parametrization possibilities as HIU’s, so not only a lookuptable anymore
We added more information, and information filters on HIU's